نوع مقاله : مقاله پژوهشی
عنوان مقاله English
نویسندگان English
In this study, a Hardware-in-the-Loop (HIL) framework is presented for the laboratory evaluation of pump-inverter drives in water distribution systems. The platform includes an electric pump, a variable frequency drive, and a stepper valve as a controllable hydraulic load, integrated with the real-time simulation of the remaining water network. To validate the HIL simulation results, a mathematical model was developed and implemented in a Model-in-the-Loop (MIL) configuration. Comparative analyses demonstrate a very close agreement between the two methods. The Root Mean Square Error (RMS) for the output flow rate, discharge pressure, and pressure drop was found to be 0.18 lpm, 0.009 MPa, and 0.011 MPa, respectively, with a maximum relative difference of less than 4.1%, confirming the high accuracy of the proposed system. Static and dynamic tests were conducted to identify system behavior. In static tests, the relationship between valve opening, flow rate, and pressure at various motor speeds was examined, while dynamic tests demonstrated the framework’s capability to reproduce transient responses and capture nonlinear effects such as hysteresis. Furthermore, a variable frequency drive equipped with a Proportional-Integral-Derivative (PID) controller was utilized for pressure regulation, exhibiting stable and robust performance under varying initial conditions. The results indicate that the developed HIL simulation approach is effective for studying the performance and control of pump-inverter systems, providing a suitable balance between laboratory realism and modeling flexibility.
کلیدواژهها English