Computation of discharge and discharge coefficient of subcritical flow in trapezoidal flumes with prismatic pier under free flow conditions

Document Type : Research Article

Authors

1 Department of Water Engineering, Islamic Azad University, Khoy Branch, Khoy, Iran

2 Department of Water Engineering, Faculty of Engineering, Islamic Azad Universiyy, Khoy Branch, Khoy, Iran

Abstract

One of the simple and cheap ways for flow measurement in canals is to use flumes. In this study, the efficiency of trapezoidal flumes with prismatic piers for flow measurement in trapezoidal canals was investigated. Laboratory investigations on four prismatic piers installed in the trapezoidal canal floor with an adjustable side slope were conducted. Based on the results of conducting several experiments, in the first analysis, a relationship and graph to calculate the discharge for each side slop and a relationship for all of the investigated side slopes were separately presented using dimensional analysis. In the second analysis the relationship and graph to calculate the discharge coefficient for each side slope and a single relationship for all of the investigated side slopes were separately obtained through the simultaneous use of the concept of energy principle and dimensional analysis. To investigate the accuracy of the obtained relationships, the statistical parameter of Mean Absolute Relative Error (MARE) was used. In the first analysis the mean value of the relative error to estimate the discharge in the investigated side slopes (z=0.268, 0.4663, 0.7 and 1) were 8.8, 10, 7.7 and 8.3 percent, respectively. Also in the second analysis, the value of this statistical parameter to estimate the discharge in the investigated slopes were 6.5, 10, 1.8 and 3.4 percent respectively and based on the single relationship for all of the investigated side slopes was 9%. Therefore, to calculate the discharge, the second analysis was recognized to be more appropriate than the first.

Keywords

Main Subjects


[1] A. J. Clemmens, M. G. Bos, J. A. Replogle, FLUME, Design and Calibration of Long-Throated Measuring Flumes. International Institute for Land Reclamation and Improvement Wageningen, The Netherland, (1993) 117.
[2] M. G. Bos, Long-throated flumes and broad-crested weirs, International institute for land Reclamation  and improvement, Wageningen, The Netherland, (1985) 156.
[3] W. H. Hager, Modified trapezoidal venture channel. Journal of Irrigation and drainage engineering, 112(3) )1986( 225-241.
[4] W. H. Hager, Mobile flume for circular channel. Journal of Irrigation and drainage engineering, 114(3) (1988) 520-534.
[5] Z. Samani, H. Magallanez, Hydraulic characteristics of a circular flume. Journal of Irrigation & Drainage Engineering,  117(4) (1992) 559-567.
[6] Z. Samani, H. Magallanez, Measuring water in trapezoidal canals. Journal of Irrigation & Drainage Engineering. 119(4) (1993) 181-189.
[7] Z. Samani, H. Magallanez, Simple Flume for Flow Measurement in Open Channels. Journal of Irrigation & Drainage Engineering, 126(2) (2000) 127-129.
[8] A. Peruginelli, F. Bonacci, Mobile prisms for flow measurement in rectangular channels. Journal of Irrigation and Drainage Engineering, 123(3) (1997) 170174.
[9] K. S. Prabhata, Discussion of “Mobile prisms for flow measurement in rectangular channels” by A. Peruginelli, and F. Bonacci, Journal of Irrigation and Drainage Engineering, 124(5) (1998) 279-280.
[10] A. Goel, On a flow meter for discharge measurement in irrigation channels. Flow Measurement and Instrumentation 17(5) (2006) 255-257.
[11] V. L. Manekar, P. D. Porey, R. N. Ingle, Discharge relation for cutthroat flume under free-flow condition.
Journal of Irrigation and Drainage Engineering, 133(5) (2007) 495-499.
[12] R. P. Willeitner, S. L. Barfuss, M. C. Johnson, Montana Flume Flow Corrections under Submerged Flow, Journal of Irrigation and Drainage Engineering, 138(7) (2012) 685-689.
[13] H. A. Hayawi, A. A. Yahya, G. A. Hayawi, Analysis of hydraulic characteristics of cutthroat flume.  Al-Rafidain Engineering Journal (AREJ),  21(4) (2013) 131-141.
[14] F. G. Carollo, C. Di Stefano, V. Ferro, V. Pampalone, New Stage-Discharge Equation for the SMBF Flume,
Journal of Irrigation and Drainage Engineering 142(5) (2016) 1-5.
[15] V. Ferro, Simple flume with a central baffle. Flow Measurement and Instrumentation, 52 (2016) 53–56.
[16] F. Lotfi Kolavani M.Bijankhan, C.Di Stefano, V.Ferro, A.Mahdavi Mazdeh, Flow measurement using circular portable flume, Flow Measurement and Instrumentation, 62 (2018) 76-83  
[17] M. Bijankhan, V. Ferro, Experimental study on triangular central baffle flume. Flow Measurement and Instrumentation, 70 (2019) 101641.
[18] M. Mohammadi, A. Vatankhah, Flow measurement flume with cylindrical and conical walls. Iranian soil and water researches, 51(7) (2020) 1637-1651 (in Persian).
[19] G. V. Skogerboe, R. S. Bennett, W. R. Walker, Generalized discharge relations for cutthroat flumes, Journal of Hydraulic Division, 98(4) (1972) 596-583. 
[20] G. V. Skogerboe, M. L. Hayatt, Analysis of submergence in flow measuring flumes, Journal of Hydraulic Division, .002-381 (7691) (4)39.