An Investigation into the Impact of Fire on Lateral Stability and Strength of Thin Steel Plate Shear Walls

Document Type : Research Article

Authors

1 Phd Candidate, civil faculty, semnan university

2 ferdowsi university

Abstract

The SPSWs has been enthusiastically applied in some of the tall buildings across the world as a novel lateral load-bearing system and due to their proper stiffness, strength, ductility, and energy absorption, as well as remarkable reduction in buildings’, weigh compared to the concrete cases, they are deemed as an efficient alternative for the traditional load-resisting systems. Fire-related hazards and their impacts on the structural systems have been of major concern for practitioners, which is of utmost significance for special structures and tall buildings. Accordingly, in the case of thin steel plate shear walls, fire is most likely to leave detrimental effects on the lateral stability and strength of them due to their small values of thickness. To better understand the behavior of such systems in the event of a fire, this paper aims to investigate the impact of heat caused by a fire on the stability, elastic stiffness and yield strength of a 3-storey frame equipped with SPSW system. Based on the results derived by connected stress-heat analyses, thickening the wall results in a substantial reduction in the column’s deformations. Moreover, an increase in thickness and yield strength of the steel plate plays an effective role in less reduction in yield strength and elastic stiffness of the system after fire events although, while the plate thickness is kept constant, the system’s elastic stiffness does not vary as the yield strength raises. In addition, simple relations were achieved to estimate the post-fire elastic stiffness and yield strength of the SPSW system.

Keywords

Main Subjects


[1]Thorburn, L., Kulak, G., Montgomery, C., "Analysis of Steel Plate Shear Wall", Structural Engineering Report No. 107, Department of Civil Engineering, University of Alberta, Edmonton, Alberta, Canada, 1983.
[2]Timler, P., Kulak, G., "Experimental Study of Steel Plate Shear Wall", Structural Engineering Report No. 114, Department of Civil Engineering, University of Alberta, Edmonton, Alberta, Canada, 1983.
[3]Roberts, T., Sabouri-Ghomi, S., "Hysteretic Characteristics of Unstiffend Perforated Steel Plate Shear Panels", Thin Walled Structures, 1992, 14, 139-151.
[4]Vian, D., Bruneau, M., "Testing of Special LYS Steel Plate Shear Walls", Proceeding of the 13th World Conference on Earthquake Engineering, Paper No.978, Vancouver British Columbia, Canada, 2004.
[5]Gholhaki, M., "Study of Behavior of Thin Steel Plate Shear Walls and Effect of Beam to Column Connections", PhD Thesis, K.N. Toosi University of Technology, Tehran, Iran, 2007.
[6]Sabouri-Ghomi, S., Roberts, T., "Nonlinear Dynamic Analysis of Steel Plate Shaer Walls Including Shear and Bending Deformations", Engineering Structural, 1992, 5, 309-317.
[7]National Institue of Standards and Technology, Federal Building and Fire Safety Investigation of the World Trade Center Disaster, Department of Commerce USA, 2005.
[8]Liew J. Y. R., Chen, H., "Explosion and fire analysis of steel frames using fiber element approach," Journal of Structural Engineering, 2004, 130(7), 991–1000.
[9]Liew J. Y. R., Chen, H., "Direct analysis for performancebased design of steel and composite structures", Progr Struct Engrg Mater, 2004, 6(4), 213–228.
[10]Kuo-Chen, Y., Sheng-Jin, C., Cun-Ci, L., Hung-Hsin, L., "Experimental study on local buckling of fire-resisting steel columns under fire load", Journal of Constructional Steel Research, 2005, 61, 553–565.
[11]Liew J. Y. R., "Survivability of steel frame structures subject to blast and fire", Journal of Constructional Steel Research, 2008, 64, 854–866.
[12]Dong, Y. L., Zhu, E. C., Prasad, K., "Thermal and structural response of two-storey two-bay composite steel frames under furnace loading", Fire Safety Journal, 2009, 44, 439–450.
[13]Ruirui, S., Zhaohui, H., Ian, B., "Progressive collapse analysis of steel structures under fire conditions", Engineering Structures, 2012, 34, 400–413.
[14]Madsen, R. L., Castle, T. A., Schafer, B. W., "Seismic Design of Cold-Formed Steel Lateral Load-Resisting Systems: A Guide for Practicing Engineers", Gaithersburg, MD, 2016, http://dx.doi.org/10.6028/NIST.GCR.16-917-38.
[15]Wang, X., Hutchinson, T. C., Hegemier, G., Gunisetty, S., Kamath, P., Meacham, B., "Earthquake and fire performance of a mid-rise cold-formed steel framed building–test program and test results," rapid release (preliminary) report (SSRP-2016/07), San Diego, CA, 2016.
[16]Hoehler, M. S., Smith C. M., Hutchinson, T. C., Wang, X., Meacham, B. J., Kamath., P., "Behavior of steel-sheathed shear walls subjected to seismic and fire loads", Fire Safety Journal, 2017, 91, 524-531.
[17]Abaqus Standard User’s manual, Version (6.10.1), Karlsson and Sorensen, 2012.
[18]Schleich, J. B., Bouillette, J. P., Hass, R., Preston, R., Sandman, T., "International Fire Engineering Design for Steel Structures, State of the Art. Brussels", Belgium, International Iron and Steel Institute, 1993.
[19]Schleich, J. B., Cajot, L. G., Pierre, M., Brasseur, M., Franssen, J. M., Kruppa, J., Joyeux, D., Twilt, L., Van Oerle, J., Aurtrnrtxe, G., "Development of Design Rules for Steel Structures Subjected to Natural Fires in Large Components", European Commission, Technical Steel Research, Report EUR 18868 EN, 1999.
[20]American Society of Civil Engineers, Standard Calculation Methods for Structural Fire Protection, ASCE/SFPE, Standard 7-05, 2005.
[21]American Society for Testing and Materials, Standard Methods of Fire Tests of Building Construction and Materials, ASTM Standard E119-05, 2005.
[22]Lie, T. T., "Fire Temperature-Time Relations", Chapter 4-8 of the SFPE Handbook of Fire Protection Engineering, Third Edition, 2002.