<ArticleTitle>Study of the Effect of Porcelain Sheathing Direction on the Lateral Resistance of Cold-Formed Steel Shear Wall under Constant Gravity Loading by Experiment</ArticleTitle>
<VernacularTitle>Study of the Effect of Porcelain Sheathing Direction on the Lateral Resistance of Cold-Formed Steel Shear Wall under Constant Gravity Loading by Experiment</VernacularTitle>
			<FirstPage>653</FirstPage>
			<LastPage>676</LastPage>
			<ELocationID EIdType="pii">5436</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ceej.2024.22451.7984</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Saeedreza</FirstName>
					<LastName>Sowlat-tafti</LastName>
<Affiliation>Department of Civil Engineering, Taft Branch, Islamic Azad University, Yazd, Iran.</Affiliation>

</Author>
<Author>
					<FirstName>Mohammadreza</FirstName>
					<LastName>Javaheri-tafti</LastName>
<Affiliation>Civil Eng. Deprt., Yazd Branch, Islamic Azad Univ., Yazd, Iran.</Affiliation>
<Identifier Source="ORCID">0000-0001-6860-0705</Identifier>

</Author>
<Author>
					<FirstName>Hamidreza</FirstName>
					<LastName>Ronagh</LastName>
<Affiliation>School of Civil Engineering, The University of Queensland, Brisbane, Australia</Affiliation>
<Identifier Source="ORCID">0000-0001-7826-5760</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>06</Month>
					<Day>18</Day>
				</PubDate>
			</History>
		    <Abstract>The lateral behavior of cold-formed steel shear wall is dependent on several factors including the type of sheathing used. However, only a limited number of sheathing types have been studied using specific installation method. In this study, due to the high demands of builders to use local materials for sheathing light steel frames, which, in addition to being abundant and easy to obtain, can also create a variety of designs such as stone or brick to match the facade of existent parts of the building, two full-scale samples of cold-formed steel shear walls in dimensions of 1.2×2.4 meters sheathed by porcelain ceramic with different configurations have tested under combined constant gravity loading and standard cyclic lateral loading regime. After calculation of ductility and response factors by using of specimens tests results, The seismic effect of the sheathing rectangular pieces orient, which can be installed in either horizontal or vertical strips, is investigated. The study also evaluates the failure modes of the systems. The results of the tests show that porcelain sheathing pieces installation in vertical strips instead of horizontal strips causes a decrease of approximately 50% in Energy Dissipation and 18% in ultimate lateral resistance without effect on seismic response modification factor, R.</Abstract>
			<OtherAbstract Language="FA">The lateral behavior of cold-formed steel shear wall is dependent on several factors including the type of sheathing used. However, only a limited number of sheathing types have been studied using specific installation method. In this study, due to the high demands of builders to use local materials for sheathing light steel frames, which, in addition to being abundant and easy to obtain, can also create a variety of designs such as stone or brick to match the facade of existent parts of the building, two full-scale samples of cold-formed steel shear walls in dimensions of 1.2×2.4 meters sheathed by porcelain ceramic with different configurations have tested under combined constant gravity loading and standard cyclic lateral loading regime. After calculation of ductility and response factors by using of specimens tests results, The seismic effect of the sheathing rectangular pieces orient, which can be installed in either horizontal or vertical strips, is investigated. The study also evaluates the failure modes of the systems. The results of the tests show that porcelain sheathing pieces installation in vertical strips instead of horizontal strips causes a decrease of approximately 50% in Energy Dissipation and 18% in ultimate lateral resistance without effect on seismic response modification factor, R.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Cold-formed steel shear wall</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">porcelain sheathing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hysteretic cycle</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">sheathing strips direction</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">constant gravity loading</Param>
			</Object>
		</ObjectList>