<ArticleTitle>Evaluation of variable speed pumps in pressurized water distribution systems</ArticleTitle>
<VernacularTitle>Evaluation of variable speed pumps in pressurized water distribution systems</VernacularTitle>
			<FirstPage>1773</FirstPage>
			<LastPage>1788</LastPage>
			<ELocationID EIdType="pii">4449</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ceej.2021.19867.7277</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Arian</FirstName>
					<LastName>Salmasi</LastName>
<Affiliation>Applied Chemistry Student, Faculty of Chemistry, University of Tabriz</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2021</Year>
					<Month>04</Month>
					<Day>16</Day>
				</PubDate>
			</History>
		<Abstract>In pressurized water distribution systems, a constant speed pump is often used because of its simplicity. However, constant speed pipes are not easily able to deal with changing demands in water flows. When the demand for the discharge differs from the design discharge, the required demand (discharge and head) could be met by changing the pump speed without making any special changes in the system. Using an electronic drive circuit, the electrical frequency can be changed and the rotation speed of the pump motor can thus be modified. In this study, the application of variable speed pumps in pressurized irrigation systems is investigated. Two pumping station scenarios including a fixed speed pump and a variable speed pump are considered. The results show that using a variable speed pump increases the average pump efficiency by 18.7%. In addition, the variable speed pump system reduces the electrical consumption 57.6 % compared to a fixed speed pump. Therefore, the use of variable speed pumps in pressurized systems is recommended.</Abstract>
			<OtherAbstract Language="FA">In pressurized water distribution systems, a constant speed pump is often used because of its simplicity. However, constant speed pipes are not easily able to deal with changing demands in water flows. When the demand for the discharge differs from the design discharge, the required demand (discharge and head) could be met by changing the pump speed without making any special changes in the system. Using an electronic drive circuit, the electrical frequency can be changed and the rotation speed of the pump motor can thus be modified. In this study, the application of variable speed pumps in pressurized irrigation systems is investigated. Two pumping station scenarios including a fixed speed pump and a variable speed pump are considered. The results show that using a variable speed pump increases the average pump efficiency by 18.7%. In addition, the variable speed pump system reduces the electrical consumption 57.6 % compared to a fixed speed pump. Therefore, the use of variable speed pumps in pressurized systems is recommended.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Pumping station</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">variable speed pump</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">pressurized pipe</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">EFFICIENCY</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">pump power</Param>
			</Object>
		</ObjectList>