<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه صنعتی امیرکبیر</PublisherName>
				<JournalTitle>نشریه مهندسی عمران امیرکبیر</JournalTitle>
				<Issn>2588-297X</Issn>
				<Volume>52</Volume>
				<Issue>6</Issue>
				<PubDate PubStatus="epublish">
					<Year>2020</Year>
					<Month>08</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Experimental investigation on hexagonal steel tubular columns filled with plain and 
fiber reinforced concrete under eccentric compression load</ArticleTitle>
<VernacularTitle>بررسی آزمایشگاهی ستون‌های فولادی شش ضلعی پر شده با بتن ساده و الیافی تحت بار فشاری خارج از مرکز</VernacularTitle>
			<FirstPage>1379</FirstPage>
			<LastPage>1404</LastPage>
			<ELocationID EIdType="pii">3302</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ceej.2019.15365.5896</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>نوید</FirstName>
					<LastName>مهدوی</LastName>
<Affiliation>فارغ التحصیل رشته‌ی مهندسی سازه، دانشگاه فردوسی مشهد، دانشکده‌ی مهندسی، گروه عمران</Affiliation>

</Author>
<Author>
					<FirstName>میلاد</FirstName>
					<LastName>سلیمی</LastName>
<Affiliation>فارغ التحصیل رشته‌ی مهندسی سازه، دانشگاه فردوسی مشهد، دانشکده‌ی مهندسی، گروه عمران</Affiliation>

</Author>
<Author>
					<FirstName>منصور</FirstName>
					<LastName>قلعه‌نوی</LastName>
<Affiliation>عضو هیئت علمی و دبیر گرایش مهندسی و مدیریت ساخت/ دانشگاه فردوسی مشهد</Affiliation>
<Identifier Source="ORCID">0000-0002-1667-7812</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>11</Month>
					<Day>29</Day>
				</PubDate>
			</History>
		    <Abstract>Due to the advantages of Concrete Filled Tube columns (CFT), their attention is increasingly on the rise. Despite the great research done in these sections, in some cases, as in the case of less frequent sections or using different types of concrete, the need for research to complete the design criteria and guidelines seems necessary. The present study was conducted with an experimental approach to study the behavior of CFT columns under eccentric load. In this study, 8 CFT columns with a hexagonal cross-section of 150 cm in length were tested. Concrete used as the core of the samples was simple concrete and fiber concrete. The displacements in two directions of the longitudinal and lateral has been recorded and the force-displacement diagram for all samples in both directions has been drawn. Parameters such as bearing capacity, ductility index, energy dissipation and effective hardness have been analyzed and compared. Based on the comparison of the results, it was found that in columns that are only under axial load, the increase in concrete core strength significantly increases the bearing capacity of the specimens, so that an increase of about 50% of the concrete core strength causes an increase of about 20% of the loaded capacity of the specimen; However, by increasing the bending moment, the effect of concrete core resistance is greatly reduced. Also, it was found that specimens filled with fiber concrete have a greater ability to maintain effective hardness. It also seems that the presence of fibers in concrete affects the ductility and energy dissipation parameters.</Abstract>
			<OtherAbstract Language="FA">به علت مزایای مناسب ِ سازه‌ای ستون‌های فولادی پر شده با بتن (CFT) ، توجه به آن‌ها به‌صورت روزافزون در حال افزایش است. باوجود تحقیقات بسیار زیاد انجام‌شده در رابطه با این مقاطع همچنان در برخی موارد همانند شکل مقاطعی که کمتر متداول هستند و یا استفاده از انواع مختلف بتن، نیاز به پژوهش‌هایی در جهت تکمیل ضوابط و دستورالعمل‌های طراحی ضروری به نظر می‌رسد. پژوهش حاضر با رویکرد آزمایشگاهی به مطالعه‌ی رفتار ستون‌های فولادی پر شده با بتن تحت بار خارج از مرکز پرداخته است. در این پژوهش 8 نمونه ستون CFT با مقطع شش‌ضلعی و با طول 150 سانتی‌متر تحت آزمایش قرارگرفته است. بتن مورداستفاده به‌عنوان هسته‌ی مقطع از نوع بتن ساده و الیافی بوده است. تغییر مکان‌ها در دو راستای محوری و جانبی ثبت شده و نمودار نیرو - تغییر مکان برای تمامی نمونه‌ها رسم شده است. پارامترهایی نظیر ظرفیت باربری، شاخص شکل‌پذیری، جذب انرژی و سختی مؤثر مورد تحلیل و مقایسه قرار گرفته است. بر اساس مقایسه‌ی نتایج مشخص شد در ستون‌هایی که تنها تحت بار محوری خالص می‌باشند، افزایش مقاومت هسته‌ی بتنی به‌طور قابل‌توجهی ً %50 مقاومت هسته‌ی بتنی سبب افزایش ظرفیت باربری نمو‌نه‌ها را افزایش می‌دهد به‌طوری‌که افزایش حدودا ً %20 ظرفیت باربری می‌شود؛ اما با ایجاد لنگر و افزایش آن از تأثیر مقاومت بتن به‌شدت کاسته می‌شود. بر حدودا اساس نتایج نمونه‌های پر شده با بتن الیافی توانایی بیشتری در حفظ سختی مؤثر از خود نشان می‌دهند. همچنین به نظر می‌رسد وجود الیاف در بتن بر شاخص‌های شکل‌پذیری و جذب انرژی تأثیرگذار است.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">نمودار نیرو- تغییر مکان</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">خروج از مرکزیت بار محوری</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ظرفیت باربری</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ضریب شکل‌‌پذیری</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">میزان جذب انرژی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ceej.aut.ac.ir/article_3302_6fab6e3aa34248ec1e34a4aeedecddc8.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
