<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Civil Engineering</JournalTitle>
				<Issn>2588-297X</Issn>
				<Volume>51</Volume>
				<Issue>3</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>08</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Effect of FRP Strips Configuration, Beam Dimensions and Amount of Tensile Rebars  on Shear Capacity of Reinforced Concrete Beams</ArticleTitle>
<VernacularTitle>Effect of FRP Strips Configuration, Beam Dimensions and Amount of Tensile Rebars  on Shear Capacity of Reinforced Concrete Beams</VernacularTitle>
			<FirstPage>465</FirstPage>
			<LastPage>478</LastPage>
			<ELocationID EIdType="pii">2874</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ceej.2018.13619.5455</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Mehrdad</FirstName>
					<LastName>Hejazi</LastName>
<Affiliation>Department of Civil Engineering, Najafabad Branch, Islamic Azad University, Najafabad, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mitra</FirstName>
					<LastName>Mohammad</LastName>
<Affiliation>Dept of Civil Engineering/Islamic Azad University, Najafabad Branch</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2017</Year>
					<Month>11</Month>
					<Day>01</Day>
				</PubDate>
			</History>
		<Abstract>In this paper, the effect of the distance, number of layers and cross-sectional area of FRP strips, the amount of longitudinal rebars, dimensions of beam and compressive strength of concrete on shear capacity of reinforced concrete beams with rectangular crosssection stiffened by FRP strips under symmetrical concentrated loads using the finite element method has been studied. For this reason, the non-linear analysis of 101 reinforced beams has been performed for evaluation of the effect of the parameters on load capacity and mid-span deflection of the beams with and without strengthening. Obtained results indicate that for a constant concrete compressive strength, increasing the width and the number of layers of FRP strips increases the load capacity compared to the control beam. By changing the layout of reinforcing strips with irregular intervals along the beam, the load capacity increase is about 6% to 35%. Also, the increase of the amount of longitudinal rebars from Φ10 to Φ14 creasing the compressive strength of the concrete from 30 MPa to 50 MPa, and increasing the cross-sectional area of the beam from 150 × 300 mm to 150 × 400 mm in unstiffened beams, increase the load capacity by 31%, 23% and 55%, respectively.</Abstract>
			<OtherAbstract Language="FA">In this paper, the effect of the distance, number of layers and cross-sectional area of FRP strips, the amount of longitudinal rebars, dimensions of beam and compressive strength of concrete on shear capacity of reinforced concrete beams with rectangular crosssection stiffened by FRP strips under symmetrical concentrated loads using the finite element method has been studied. For this reason, the non-linear analysis of 101 reinforced beams has been performed for evaluation of the effect of the parameters on load capacity and mid-span deflection of the beams with and without strengthening. Obtained results indicate that for a constant concrete compressive strength, increasing the width and the number of layers of FRP strips increases the load capacity compared to the control beam. By changing the layout of reinforcing strips with irregular intervals along the beam, the load capacity increase is about 6% to 35%. Also, the increase of the amount of longitudinal rebars from Φ10 to Φ14 creasing the compressive strength of the concrete from 30 MPa to 50 MPa, and increasing the cross-sectional area of the beam from 150 × 300 mm to 150 × 400 mm in unstiffened beams, increase the load capacity by 31%, 23% and 55%, respectively.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Reinforced Concrete Beam</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">FRP Strips</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Tensile Rebar</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Shear Capacity</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ductility</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ceej.aut.ac.ir/article_2874_e6af401c28c1790eaef7d55c92ab6ab6.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
