<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>Amirkabir Journal of Civil Engineering</JournalTitle>
				<Issn>2588-297X</Issn>
				<Volume>43</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2011</Year>
					<Month>08</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Impact of Using Knee Elements to Improve Cyclic Performance of Chevron &amp; Diagonal Braced Steel Frames</ArticleTitle>
<VernacularTitle>Impact of Using Knee Elements to Improve Cyclic Performance of Chevron &amp; Diagonal Braced Steel Frames</VernacularTitle>
			<FirstPage>51</FirstPage>
			<LastPage>59</LastPage>
			<ELocationID EIdType="pii">124</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ceej.2011.124</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>Seyedmahdi</FirstName>
					<LastName>Mehdi Zahrai</LastName>
<Affiliation></Affiliation>
<Identifier Source="ORCID">0000-0003-2759-2424</Identifier>

</Author>
<Author>
					<FirstName>Saeed Bahram</FirstName>
					<LastName>Bahram Masjedbari</LastName>
<Affiliation></Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2014</Year>
					<Month>03</Month>
					<Day>16</Day>
				</PubDate>
			</History>
		    <Abstract>Braced frames have been known as frequently used earthquake resistant systems. If a limited length of a member in such a bracing system can undergo ductile behavior, the structure would sustain in a reliable performance, dissipating a large amount of seismic energy during earthquake. Knee Braced Frames, KBFs, are among the ductile systems having such mechanisms. In this paper, single-story single-bay steel Diagonal and Chevron Knee Braced Frames (DKBF &amp; CKBF) with different configurations have been modeled using ANSYS software and their lateral behavior have been studied and compared. Comparing the hysteretic curves and ductility factors, better performance of CKBF compared with DKBF has been found due to its more knee elements and thus having higher damping. In two similar frame configurations, CKBF1 reaches to 25 mm displacement while DKBF2 displacement limits to 15 mm, such that following the same loading protocol, ductility factor of CKBF1 is 60% more than that of DKBF2.Comparing VonMises and shear stress contours for knee elements, shows the fact that the more symmetric the KBF, the more efficient the knee element in dissipating energy leading to using the whole section capacity.</Abstract>
			<OtherAbstract Language="FA">Braced frames have been known as frequently used earthquake resistant systems. If a limited length of a member in such a bracing system can undergo ductile behavior, the structure would sustain in a reliable performance, dissipating a large amount of seismic energy during earthquake. Knee Braced Frames, KBFs, are among the ductile systems having such mechanisms. In this paper, single-story single-bay steel Diagonal and Chevron Knee Braced Frames (DKBF &amp; CKBF) with different configurations have been modeled using ANSYS software and their lateral behavior have been studied and compared. Comparing the hysteretic curves and ductility factors, better performance of CKBF compared with DKBF has been found due to its more knee elements and thus having higher damping. In two similar frame configurations, CKBF1 reaches to 25 mm displacement while DKBF2 displacement limits to 15 mm, such that following the same loading protocol, ductility factor of CKBF1 is 60% more than that of DKBF2.Comparing VonMises and shear stress contours for knee elements, shows the fact that the more symmetric the KBF, the more efficient the knee element in dissipating energy leading to using the whole section capacity.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Diagonal Bracing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chevron Bracing</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Knee element</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hysteretic curve</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Stress Contour</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Ductility</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ceej.aut.ac.ir/article_124_c8ffe9a587b126f152ed3d89a146b445.pdf</ArchiveCopySource>
</Article>